Hungarian Radiology

[The role of MRI in the clinical examination following breast cancer screening]

SZABÓ Éva, BIDLEK Mária, GŐDÉNY Mária

OCTOBER 10, 2005

Hungarian Radiology - 2005;79(05)

[INTRODUCTION - Breast cancer screening was performed in 27 325 female patients at the National Institute of Oncology from 1st of January 2002 to May 30th of 2005. Complementary examinations were necessary in 1876 women. MR-mammography was performed in 65 of these cases. We were curious about in which cases MR mammography helps to make the diagnosis more accurate, how does it influence the therapy. We also studied, whether the number of surgical interventions because of benign breast lesions decreases due to MR mammography. PATIENTS AND METHODS - In 65 patients MR mammography was performed using non-contrast axial and coronal T1W and STIR sequences. After the injection of gadolinium four series of 3D FLASH (fast low angle shot) dynamic gradiens echo sequences were also applied. Subtraction of the non-contrast and contrast enhanced series were evaluated in addition to the intensity curves of the postcontrast series. RESULTS - MR mammography helped to evaluate dense breasts in 21 cases, to identify multifocal lesions in 6 cases and to differentiate the malignant-benign processes. In the course of the 65 post-screening examinations, malignant processes [BI-RADS IV-V (Breast Imaging Reporting and Data System)] were diagnosed in 21 cases, benign processes (BI-RADS II-III) or negative results were found in 44 patients. CONCLUSION - MR mammography increased diagnostic accuracy, decreased the number of benign lesion-related surgical procedures and increased the accuracy in determining surgical radicality and establishing a therapeutic plan.]

COMMENTS

0 comments

Further articles in this publication

Hungarian Radiology

[Board Meeting of the Hungarian College of Radiology]

PALKÓ András, FORRAI Gábor

Hungarian Radiology

[Networks]

LOMBAY Béla

Hungarian Radiology

[The force transmission of the distal endings of stent delivery systems]

SZIKRA Péter, VÖRÖS Erika, SZTRIHA László, SZÓLICS Alex, CSIKÁSZ Tamás

[INTRODUCTION - In cases of endovascular treatment of internal carotid artery stenosis, one of the most important aspects is to minimise embolic complications. Dislodging emboli may be influenced by the shape and size of tapered endings of stent delivery systems. Our team performed measurements and calculations on the emergence of force of the various tapered endings. MATERIAL AND METHOD - Five different commercially available stent dilivery systems were investigated. The thickness of the devices were measured and taking 5 mm normal artery diameter, the lumen size was calculated, above which the delivery system should dilate the lumen mechanically. By means of geometrical computer-constructions and measurements, we analysed the forces directed ahead and laterally, emerging on the surface of tapered endings during the passing through the stenosis. RESULTS - The stent delivery systems were between 5.0 and 5.9 F in diameter, and even the stent delivery system of lowest profile would dilate a stenosis of over 89%. The different endings are tapered with variable lengths. The force transmission on the vessel wall of different directions was distinct at the various points of the cone surfaces. The forces directed ahead were less than those directed laterally on the larger part of a cone surface. Irregularity of the cone surfaces distributed the forces unfavorably. Considering the features of tapered endings, the atraumatic introduction of the devices required a range of upper limits of stenoses between 89.76-98.04%, which are more feasible values than those deternined by shaft sizes. CONCLUSIONS - Our experimental work suggests, that the shape and size of the endings of stent delivery systems influence the forces affecting vessel wall plaques, and in this manner, embolic complications, during carotid stenting. The lowest risk of embolisation could be induced by using the longest and smoothest tapered endings.]

Hungarian Radiology

[Acromesomelic dysplasia du Pan]

KAISSI Al Ali, GHACHEM Ben Maher, CHEHIDA Ben Farid, KOZLOWSKI Kazimierz

[INTRODUCTION - Cartilage derived morphogenic protein (CDMP1) mutations account for several related disorders, ranging from prenatal lethal to very mild entities such as brachydactyly C. Two similar severe manifestations of CDMP1 mutations are du Pan and Hunter-Thompson syndromes. CASE REPORTS - We report two second degree relatives with du Pan syndrome. Clinical history and full skeletal surveys were analysed and compared with the data from the literature. Frequent spontaneous abortions - probably manifestation of the lethal forms of CDMP1 mutations - were present in both families. Skeletal surveys of the patients showed similar acromesomelic abnormalities consistent with du Pan syndrome. CONCLUSION - The rare publications of du Pan syndrome present usually insufficient radiographic documentation. Better radiographic imaging is necessary to establish clear-cut criteria of differentiation between du Pan and Hunter-Thompson syndrome.]

Hungarian Radiology

[Quality cost in radiology: the cost of repeated examinations]

KIS Zsuzsanna

[INTRODUCTION - The aim of the author is to describe the definition and types of quality cost in the health care services especially in the field of radiology. The proportion of the quality cost is based on the author's data and data from the literature. The ways of reduction of the quality cost is also discussed. MATERIAL AND METHODS - The author made a research based on a prior multicentric study to determine the loss derived from the excessive use of films used during the repeated radiological examination. The cost of wrong services nationwide is calculated on the basis of the loss per 1000 German point. RESULTS - Our short research showed that 300 000 Ft HUF + VAT per year was paid because of the excessive use of the films during the repeated examination points within the given period of time. The loss percentage per 1000 German points can be calculated based on the points generated during a given time. In this way there was more than 300 million HUF spent on defective services nationwide in 2002. CONCLUSION - The cost of defective services and resulting moral and financial losses justify the need for finding and reducing the costs. Quality control and quality improvement can be used to achieve the aims of controlling the processes by the right indicators. By discussing them the processes will improve, the costs will be lower and quality also improves. The patients and insurance companies who buy our services also have the same expectations.]

All articles in the issue

Related contents

Lege Artis Medicinae

[Brest cancer screening, early diagnosis]

LENGYEL László

[There is no data in the medical literature concerning the late results of breast physical exam by paramedical personnel as a screening test. In a population screening for breast cancer in Debrecen, nearly 70 thousand women were observed from 1981 to 1985 and 298 new breast cancer patients were detected. 198 patients were from the screened population and 100 patients from the non screened population. All of the breast cancer patients were followed up, and the analysis was completed on 31st December 1991 with the help of statistical methods. The author analysed the overall survival, cumulative death rate and relative risk of dying according to age group. The difference of overall survival was 29% for the screened group. This result is nearly the same as that produced by mammographic screening.]

Lege Artis Medicinae

[Reflections on breast cancer screening]

GÖBLYÖS Péter

[The author reviews opinions concerning advantages and disadvantages of breast cancer screening, summarizes the results of screening, and makes proposals for introducing breast cancer screening in Hungary. The urgency of this proposal is emphasized. A system of central support is necessary, but it would be worthwhile to bring this proposal to the attention of potential foreign sponsors as well. A „minimal program" should include efforts at increasing public awareness of self screening and expanded clinical examinations. The formation of „Breast Clubs” among patients and „Breast Teams” among competent physicians in each institute is considered desirable. Uniformity in the teaching of breast diagnostics and therapy is deemed important. ]

Clinical Neuroscience

[The role of sleep in the relational memory processes ]

CSÁBI Eszter, ZÁMBÓ Ágnes, PROKECZ Lídia

[A growing body of evidence suggests that sleep plays an essential role in the consolidation of different memory systems, but less is known about the beneficial effect of sleep on relational memory processes and the recognition of emotional facial expressions, however, it is a fundamental cognitive skill in human everyday life. Thus, the study aims to investigate the effect of timing of learning and the role of sleep in relational memory processes. 84 young adults (average age: 22.36 (SD: 3.22), 21 male/63 female) participated in our study, divided into two groups: evening group and morning group indicating the time of learning. We used the face-name task to measure relational memory and facial expression recognition. There were two sessions for both groups: the immediate testing phase and the delayed retesting phase, separated by 24 hours. 84 young adults (average age: 22.36 (SD: 3.22), 21 male/63 female) participated in our study, divided into two groups: evening group and morning group indicating the time of learning. We used the face-name task to measure relational memory and facial expression recognition. There were two sessions for both groups: the immediate testing phase and the delayed retesting phase, separated by 24 hours. Our results suggest that the timing of learning and sleep plays an important role in the stabilizing process of memory representation to resist against forgetting.]